Início » Produtos » Coluna vertebral » Sistema de medula espinhal de parafuso para coluna tóraco-lombar anterior A9
Nº do produtoDiâmetroComprimento (mm)
10157-(130-140)4.530/35/40
10157-(235-245)5.035/40/45
10157-(335-350)5.535/40/45/50
10157-(435-455)6.035/40/45/50/55
Nº do produtoComprimento(mm)
10137-01313mm
10137-01414mm
10137-01515mm
10137-01616mm

A9 Anterior Thoracolumbar Screw Spinal System

The A9 anterior thoracolumbar screw spinal system is made according to the spinal physiological characteristics. It is developed specially for the internal fixation of spinal column. In this system, there are fixed screws, fixed rods, gaskets, etc.

Our A9 anterior thoracolumbar screw spinal system adopts the mechanical processing and special surface treatment. Its raw materials such as titanium and titanium alloy are in line with the GB/T13810 standard. This system is in compliance with the registered product standard of the Spinal Internal Fixation System.

Package: One piece per single package

Product Features
1. The gasket design is used to reduce the stress suffered by the anterior lumbar.
2. The Low-profile designed is applied to minimize the soft tissue irritation.
3. The special crosslink plate design meets the special requirements of the anterior thoracolumbar fixation.

Package and Sterilization Treatment
The product is supplied in the non-sterile package. After originally packed with the paper plastic package, the product will be put into the plastic bag together with the Operation Instructions and the Product Qualification Certificates.

The paper plastic roll bag is used as the inner package. It is compounded from the medical dialysis paper and plastic film. The production environment is controlled with the cleanness of Class 10,000. In the cleaning shop, the package bag is cut according to the product size. Then, its one side will be sealed with the heat-sealing machine. After the bag has been used to contain the product, its other side needs to be sealed with the sealing machine.

The paper plastic, into which the product has been put, will be cleaned in the controlling area where the cleanliness is of Class 10,000. All the cleaning methods have been inspected. The product packed with this method needs no cleaning prior to use. It just needs to be treated with sterilization in accordance with the methods specified in the Product Instructions.

Related Names
Surgical Spine Product | Thoracolumbar Fracture | Lumbar Spinal Implant

Contate-nos
Endereço: No.9 Xihu Road, Wujin High-Tech industrial Park, Changzhou City, China.
Telefone: +86-519-86522226
Fax: +86-519-86221108
E-mail:
info@waston-global.com
Pessoa a contatar: Jack Lu